Insurice 2000
The Everpure Insurice series of water filters are for use with
ice machines to provide quality ingredient water and a reduction
in scale build up from dirt and dissolved minerals in the water.
Manufactured using the pre-coat filter process it provides 0.5
micron filter protection, eliminates chlorine and other off
tastes, removes cysts and organisms and inhibits the formation
of mineral deposits. The inhibition will only be effective up
to certain levels of alkalinity.
The Insurice 2000 cartridge is available as single or twin suitable
for cubers up to 600kg per day and flakers up to 950kg per day.
The single cartridge can be used in a series of heads.
Capacities of all filters may vary according to the influent
water quality, the flow rate, the line pressure and the continuity
of flow. |
 |
|
|
Description
|
Carbon block
|
|
Application
|
Ice Makers
|
|
Filtration Rating
|
0.5 micron
|
|
Operating Temp.
|
Not exceed 38 deg C
|
|
Operating Pressure
|
Max 10bar
|
|
Connections
|
3/8 NPT female
|
| |
2000 Single
|
2000 Twin
|
|
Capacity
|
300kg per day
|
600kg per day
|
|
Dimension
|
H=740 W=180
|
H=710 W=360
|
|
Part No.
|
9324-01
|
9324-02
|
|
Flow Rate
|
6.3 lt/min
|
12.7 lt/min
|
|
Installation Tips:-
- Choose an accessible location which is suitable to support the
weight of a system.
- Use approved pipe work and fittings Minimum 10mm bore. (seek
advice on high flow systems)
- Do not braze/solder fittings into mounting heads.
- Never use saddle valve for connection.
- Do not exceed service flow rate.
- Flush cartridges to drain at full flow for 5 mins.
- Install in accordance with water regulations.
- Do not connect system to water cooled condenser.
|
|
Operational Tips:-
- Change cartridges:-
- on a regular 6 month preventative basis.
- when a significant pressure drop occurs.
- at least annually.
- Always flush cartridges to drain after changing.
|
|