ROM System

The Everpure ROM system has been specifically developed for use on combi steamer ovens. As well as lime scale, dissolved minerals, heavy metals, other impurities and inadequate water flow all affect the efficient operation of steamer ovens. By incorporating 5 micron carbon block filtration, a reverse osmosis module, storage vessel, pump and automatic controls this unit is able to provide high quality, low TDS water at volumes independent of on-site conditions.

The system is available as ROM 10 and ROM 20 and in most cases is a more cost effective option than ion-exchange units.

As some steamers require water at a minimum conductivity level we recommend you discuss your application in detail with our design engineers.

Specification

Description

Reverse Osmosis

Application

Steamer Ovens

Filtration Rating

Removes 90% dissolved minerals, colloids, particulates, and organics

Operating Temp.

Should not exceed 38 degrees C

Operating Pressure

Max=9 bar  Min=4 bar

Flow Rate

16 litres/hour ROM 10

32 litres/hour ROM20

Capacity                           

100 or 200 US gal per 24hrs

Connections

3/8 push fit

Dimensions

W=230 D=110 H=650



Installation Tips:-

  • Choose an accessible location which is suitable to support the weight of a system.
  • Use approved pipe work and fittings Minimum 10mm bore. (seek advice on high flow systems)
  • Do not braze/solder fittings into mounting heads.
  • Never use saddle valve for connection.
  • Do not exceed service flow rate.
  • Flush cartridges to drain at full flow for 5 mins.
  • Install in accordance with water regulations.

Operational Tips:-

  • Change cartridges:-
    - on a regular 6 month preventative basis.
    - when a significant pressure drop occurs.
    - at least annually.
  • Always flush cartridges to drain after changing.
  • Change module according to total hardness.