The Everpure ROM system has been specifically developed for
use on combi steamer ovens. As well as lime scale, dissolved
minerals, heavy metals, other impurities and inadequate water
flow all affect the efficient operation of steamer ovens. By
incorporating 5 micron carbon block filtration, a reverse osmosis
module, storage vessel, pump and automatic controls this unit
is able to provide high quality, low TDS water at volumes independent
of on-site conditions.
The system is available as ROM 10 and ROM 20 and in most cases
is a more cost effective option than ion-exchange units.
As some steamers require water at a minimum conductivity level
we recommend you discuss your application in detail with our
design engineers.
Specification
Description
Reverse Osmosis
Application
Steamer Ovens
Filtration Rating
Removes 90% dissolved minerals, colloids, particulates, and organics
Operating Temp.
Should not exceed 38 degrees C
Operating Pressure
Max=9 bar Min=4 bar
Flow Rate
16 litres/hour ROM 10
32 litres/hour ROM20
Capacity
100 or 200 US gal per 24hrs
Connections
3/8 push fit
Dimensions
W=230 D=110 H=650
Installation Tips:-
Choose an accessible location which is suitable to support the
weight of a system.
Use approved pipe work and fittings Minimum 10mm bore. (seek
advice on high flow systems)
Do not braze/solder fittings into mounting heads.
Never use saddle valve for connection.
Do not exceed service flow rate.
Flush cartridges to drain at full flow for 5 mins.
Install in accordance with water regulations.
Operational Tips:-
Change cartridges:-
- on a regular 6 month preventative basis.
- when a significant pressure drop occurs.
- at least annually.